Iraqi Journal of Civil Engineering
Login
Iraqi Journal of Civil Engineering
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Authorship
    • Article Processing Charges (APC)
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
    • Reviewers of IJCE
  • About
    • About Journal
    • Aims and Scope
    • Editorial Team
    • Journal Insights
    • Peer Review Process
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Open Access
    • Archiving Policy
    • Journal Funding Sources
    • AI Usage and Disclosure Policy
    • Announcements
    • Contact

Search Results for Akram S. Mahmoud

Article
Time-dependent Analysis of FRP Reinforced Two – way Slabs subject to high level stresses.

Lina Ali, Akram Mahmoud

Pages: 52-69

PDF Full Text
Abstract

The present study, the effect of changes that developed in concrete structures with time is presented. Two way slab investigated experimentally by [1]was analyzed using finite element method by ANSYS commercial program. Many parameters studied such as length to thickness ratio, reinforcement ratio and ultimate load ratio. The slab with dimension (2360*2360*63) mm and reinforced with different types of materials such as steel bars ,GFRP and CFRP (fiber reinforced polymer) bars . The results show that the strain increase gradually with time after apply the load. It can see that the strain in steel model increase with ratio of 19.98% when the load increase from 75% to 90%,and decrease with ratio 50% when the load decrease from 75% to 50% .That is, the change by increasing the strain is less and slower than the change by decreasing the strain, since the strain when dropping the load is less than the strain when lifting the load, because the structure has not undergone and its stiffness is still high and it is trying to recover its original shape. It increases significantly at the beginning, and then the difference decreases or stabilizes approximately after 330 days.

Article
Flexural behavior of beams reinforced by GFRP bars with CFRP sheets immersed in epoxy as shear

Maadh G. Alkubaisi ., Abdulkader.I Alhadithy ., Akram S. Mahmoud .

Pages: 1-8

PDF Full Text
Abstract

Corrosion in steel bars is considered a big problem because corrosion is mainly responsible of decrease virtual age of structures and many risks indicated by deterioration. In addition, corrosion increases the cost of maintenance, particularly structures exposed to harsh environmental condition. FRP bars (Fiber Reinforced Polymer) became an alternative material from traditional steel bars. FRP had properties made it used in civil engineering sectors which are lightweight, non-corrosive, non-conductive made it a preferred alternative from steel bars in aggressive environments. FRP bars don’t have yield made it con not bind outside its linear behavior to make ties, because of the brittle behavior of FRP bars up to failure. So that, the new innovative manner by using CFRP sheets stirrups immerged by sikadur330 for produce beams can resist the harsh condition and purely reinforced with FRP in a new manner can provide stirrups in full different sizes and with lower cost. Twelve beams reinforced with GFRP bars in three different ratios of tension reinforcement (four beams for each ratio). Three control beams with steel stirrups: two beams were designed to fail in shear. Whilst, the residual nine beams with shear reinforcement made from CFRP sheets strips, immerged by sikadur330. The main variable were studied is the change in type and amount of secondary reinforcement and change in amount of primary reinforcement. The test was conduct under four point loading and in simply supported conditions. The result of tested beams illustrated that, beams had a higher percentage of tension reinforcement and shear reinforcement displayed an increasing in ultimate load about 38.1% from related control beam. While, an equivalent amount of shear reinforcement displayed an increasing in carrying load capacity up to 10%. In maximum ratio of CFRP sheets immerged by sikadur330 stirrups convert failure mode from shear to flexural indicated by crushing in cover of concrete. In addition, increased energy absorption, changed cracks orientation, increased energy absorption, decrease principal strain and increased concrete tensile.    

Article
State-Of-Art of One- And Two-Way Voided Reinforced Concrete Slab

Hend Zayan, Aseel Abdaljader, Ibtihal Mawlood, Akram Mahmoud

Pages: 118-130

PDF Full Text
Abstract

A voided slab is an innovative type of reinforced concrete slab system developed recently, that has proven its excellence in terms of its structural, environmental, and economic benefits. The self-weight of a slab can be considerably reduced using different shapes of void formers like spherical, cubical, and donut. All researchers confirm that the self-weight of the slab decreases by up to 40%. Various researchers have carried out experimental and numerical studies for studying one-way flexural strength and punching shear strength of voided reinforced concrete slabs. However, the one-way or two-way flexural strength of the voided slab still needs to be acutely investigated. This paper deals with the survey on many titles of selected high impacted journals to illustrated almost criteria of investigations of these types of slabs. The main outcomes of this paper are the term environmental protection, sustainable and plastic waste reduction had a role not a little in this research, as 16% of the research on this topic were studied. Also, the plastic material governs the subject of the raw materials used to make the voids;43% of researches used this material.

Article
Ductility and Toughness of Unsymmetrical CFRP Strengthening of Reinforced Concrete Beams

Abdulsalam M. Njeman, Akram S. Mahmoud

Pages: 10-25

PDF Full Text
Abstract

The use of externally bonded composite materials such as carbon fiber reinforced polymers (CFRP) sheets is a modern and convenient way for strengthening and repairing reinforced concrete (RC) beams. This study presents experimental investigations on the flexural behavior of reinforced concrete beams strengthened by unsymmetrical CFRP sheets with various configurations. Effects of number of which strengthened faces of strengthening and fiber direction on the flexural strength of RC beams are examined. Six RC beams with dimensions of 100 mm * 220 mm were casted and tested under two points loading. One beam considered as a reference (unstrengthened) beam. Five residual beams were strengthened using CFRP sheets with various configurations. From the results, it was observed that all strengthened beams showed higher ultimate load capacity than that of the control beam. On the other hand, it was found that a progressive reduction in flexural ductility and toughness of beams with strengthening in one face and two faces with horizontal fiber direction. The highest decrease in flexural ductility and toughness for strengthened beams with horizontal fiber direction in comparison to control beam were 63% and 54%, respectively. On the contrary, the flexural ductility and toughness of strengthened beams increased with strengthening by vertical fiber direction. Additionally, the maximum percentage of increase in flexural ductility and toughness were 41% and 54%, respectively in comparison with control beam.

Article
Ductility, Toughness, and Flexural Performance of Hybrid Foamed- Normal Concrete Beams

Angham Jaffal, Ameer Hilal, Akram Mahmoud

Pages: 97-106

PDF Full Text
Abstract

A study examined the ductility and toughness properties of beams made of reinforced concrete, including foamed, normal, and hybrid beams. Nine reinforced concrete beams were produced: three foamed concrete beams, three normal concrete beams, and three hybrid concrete beams. Each beam possessed identical rectangular cross-sectional dimensions of 1500 mm × 250 mm × 150 mm. The flexural parameters (ultimate load, ductility, deflection, and durability) were assessed for each type of concrete utilized. The study's results showed that the load-bearing capacity of hybrid concrete beams was comparable to that of normal concrete beams, whereas foamed concrete beams exhibited slight improvement in their ability to carry loads. The ductility of reinforced foamed concrete beams was lesser than that of normal concrete. For over-reinforced beams, the ductility of hybrid concrete beams showed a significant improvement of 61% compared to foamed beams and an even more significant increase of 91.7% compared to normal beams. Furthermore, the hybrid concrete beam with over-reinforcement had a flexural toughness of 18.7% greater than the normal concrete beam. Suggested that a hybrid section comprising conventional and foamed concrete be utilized to decrease ductility and improve stiffness.

Article
Punching Shear Resistance of High Strength GFRP Reinforced Concrete Flat Slabs

Ibrahim A. Sarhan, Akram S. Mahmoud, Mohamed A. Hussian

Pages: 72-93

PDF Full Text
Abstract

This study program has been arranged to test the behavior of punching shear for concrete slabs reinforced by an embedded glass fiber reinforced polymer (GFRP) reinforcements. However, the shear resistance of concrete members in general and especially punching shear of two-way RC slabs, reinforced by GFRP bars has not yet been fully investigated. Seven decades ago, many researches have been carried out on punching shear resistance of slabs reinforced by conventional steel and several design methods were created. However, these methods can be not easily applied to FRP-reinforced concrete slabs due to the difference in mechanical properties between (FRP) and steel reinforcement. sixteen specimens are to be cast in lab within two categories of reinforcements such as GFRP and equivalent steel reinforcements. In addition, based on experimental data obtained from the author’s study and ACI model, the paper performed an evaluation of accuracy of proposed model. The results from the evaluation show that the ACI-formula gave inaccurate results with a large scatter in comparison with the test results of this study. A new design formula can be proposed for more accurate estimation of punching shear resistance of (GFRP) specimens.

Article
Behaviour of RC-Deep Beam by GFRP Rubberized Concrete

Omaima. Jumaa, Ahmed Noaman, Akram Mahmoud

Pages: 34-44

PDF Full Text
Abstract

In this study, the structural behaviour of RC-deep beams of glass fibre-reinforced polymer (GFRP) rubberized concrete is investigated. Rubberized concrete is manufactured by replacing fine sand aggregate with rubber crumbs in volumetric replacement ratios. The main variables were the crumb rubber content (0%, 10%, and 20%) and the main reinforcement ratio. Tested Six samples of deep beams with different dimensions (b = 150, h = 300 mm, L= 1400 mm) were under a four-point load until failure. The parameters under investigation were the mechanical properties of mixtures, load-midspan deflection curves, toughness, and the load-strain relationship. The results indicate that the increased crumb rubber content led to a decrease in the mechanical properties of rubberized concrete mixtures. It was found that the behaviour of all samples of rubberized concrete affected the deflection load curve, the ultimate load, and the increase in deflection. The sample R2-10% Rub showed the highest toughness among the tested samples, with an increase of 301.6% compared to the reference.

Article
Experimental Investigation on Mechanical Properties of Normal Concrete Reinforced with Discarded Steel Fibres

Rawaa Obaid, Ahmed Noaman, Akram Mahmoud

Pages: 1-9

PDF Full Text
Abstract

This study presents an investigation of the mechanical properties of normal concrete reinforced with discarded steel fibers (DSFs) resulting from tire manufacturing. DSFs were added to concrete in two different volume fractions of (0.25 %, and 0.5 %), and these fibers have dimensions of (40 mm length×0.92 mm diameter). The results showed that the compressive strength of the concrete was enhanced by (8.8%, and 3.3%) by adding of DSFs. However, the workability of concrete decreased at all added ratios. While the density is slightly changed. Also, the results indicate that the modulus of elasticity shows slight increases by (3.06%, and 2.25%). Additionally, the incorporation of DSFs improves the splitting tensile strength and modulus of rupture significantly. For concrete mixes having volume fractions of 0.25% and 0.5%, the splitting tensile increased by (7.89%, and 23.68%), and the modulus of rupture increased by (6.67% and 25.58%), respectively. It was concluded that using this type of discarded fibers can improve the mechanical properties of concrete as an alternative type for other types of industrial fibers.

1 - 8 of 8 items

Search Parameters

Journal Logo
Iraqi Journal of Civil Engineering

University of Anbar

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY 4.0 Logo Licensed under CC-BY-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

       
Copyright © 2025 College of Engineering, University of Anbar. All rights reserved, including those for text and data mining, AI training, and similar technologies.