Iraqi Journal of Civil Engineering
Login
Iraqi Journal of Civil Engineering
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Authorship
    • Article Processing Charges (APC)
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
    • Reviewers of IJCE
  • About
    • About Journal
    • Aims and Scope
    • Editorial Team
    • Journal Insights
    • Peer Review Process
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Open Access
    • Archiving Policy
    • Journal Funding Sources
    • AI Usage and Disclosure Policy
    • Announcements
    • Contact

Search Results for low-velocity-impact

Article
Behaviour of Waste Plastic Fiber Concrete Slabs Under Low Velocity Impact

Abdulkader Al-Hadithi, Ahmed Al-Ejbari, Ghassan Jameel

Pages: 135-148

PDF Full Text
Abstract

This research investigates the impact resistance of concrete slabs with different volume perecentage replacement ratios of waste plastic fibers (originaly made from soft drink bottles) as follows : 0.5%, 1% and 1.5%. Reference mix produced in order to compare the result. For the selected mixes, cubes with (100×100×100mm) were made to test compressive strength at age of (90) days. Flexural strength (Modulus of Rupture) test was also conducted using prisms sample of (500*100*100 mm) dimensions. The low-velocity impact test was conducted by the method of repeated falling mass where 1400gm steel ball was used. The ball falling freely from height of 2400mm on concrete panels of (500×500×50 mm) having a mesh of waste plastic fiber.The number of blows that caused first crack and final crack (failure) were determined, according to the former obtained results , the total energy was calculated. Results showed an improvement in mechanical properties for mixes containing plastic fibers compared with reference mix. For compressive strength the maximum increase in compressive strength was equal to (3.2%) at age of (90) days. Flexural strengths for mixes containing plastic fiber at ages 28, and 90 days are higher than that of these of reference mix. The maximum value of increaseing was (18%) for 28 days age of test and it was equal to (26%) for 90 days age of test for the mixture with plastic fiber content by volume equal to (1%) . Results showed a significant improvement in low-velocity impact resistance of all mixes contining waste plastic fibers when comparing with reference mix. Results illustrated that mix with (1.5%) waste plastic fibers by volume give the higher impact resistance at failure than the others. The magnitude of an increase over reference mix was equal to (340%).

Article
Behavior of Polymer Modified Concrete Slabs under Impact

Bayan S. Al-Numan, Abdulkader Ismail Al-Hadithi

Pages: 1-24

PDF Full Text
Abstract

This research includes the study of improving impact resistance of concrete using styrene butadiene rubber (SBR) with different weight ratios of polymer to cement 3%, 5% and 10%. Two series of polymer modified concrete (PMC) were produced the first level I with moderate compressive strength and the other level II with higher compressive strength. Cubes, prisms and panels were made as follows: Results showed an improvement in impact resistance of polymer modified concrete (PMC) over reference concrete in low-velocity and high-velocity impact properties. In conducting low-velocity impact tests, method of repeated falling mass was used: 1300gm steel ball falling freely from three heights 2400mm, 1200mm and 830mm. In high-velocity impact tests, shooting of 7.62mm bullets was applied to slab specimens from distance of 15m. The improvements were significant in low velocity impact resistance. The maximum increases were (33.33%, 75% and 83.33%) at ultimate failure for falling mass heights 2400mm, 1200mm and 830mm respectively. In high-velocity impact strength tests, maximum reductions recorded in spalling area were (18.5% and 27%) for polymer modified concrete (level I) with moderate compressive strength and polymer modified concrete (level II) with higher compressive strength.Maximum reductions recorded in scabbing area were (11.42% and 35.6%) for polymer modified concrete (level I) with moderate compressive strength and polymer modified concrete (level II) with higher compressive strength, respectively.

Article
Investigation on the effect of Polyethylene Terephthalate (PET) fiber and crumb rubber on energy absorption capacity of concrete

Fatima Mahmoud, Ahmed Noaman

Pages: 13-25

PDF Full Text
Abstract

The accumulation of wastes, especially plastic and car tires, has become a major problem facing society today. Therefore, through this research, these wastes were recycled and used to improve some properties of concrete. Recycled crumb rubber from car tires was used instead of sand as a partial replacement of 10%. The substitution was done by two methods: random and equivalent size substitution. As well, 1%polyethylene terephthalate (PET) fiber was added by the volume of concrete to improve some properties of rubberized concrete. Compressive strength, ultrasonic pulse velocity test (UPV) were conducted in this study to investigate the efficiency of PET rubberized concrete, as well the impact resistance test was also conducted to investigated the ability of PET rubberized concrete in term of energy absorption. Slabs of size (50cm×50cm×5cm) were utilized for low velocity impact test. The results indicated there were a reduction in compressive strength and UPV results were observed in PET fiber rubberized concrete the reduction were (37.47% and 5.4%) respectively as compared with PETC mixture and the result of dynamic modulus of elasticity show the same pattern of UPV result , in contrast there was an improvement in the impact resistance when PET fiber and crumb rubber were used it increased by(117.63% and 52.9% ) for random and equivalent replacement respectively as compared with PETC.

1 - 3 of 3 items

Search Parameters

Journal Logo
Iraqi Journal of Civil Engineering

University of Anbar

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY 4.0 Logo Licensed under CC-BY-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

       
Copyright © 2025 College of Engineering, University of Anbar. All rights reserved, including those for text and data mining, AI training, and similar technologies.