Search Results for steel-fibers

Article
High-Velocity Impact Strength of Plain and Fiber- Reinforced Polymer-Modified Concrete

Bayan S. Al-Numan .

Pages: 1-25

PDF Full Text
Abstract

AbstractThis study deals with establishing high-velocity impact properties of polymer –modified concrete (PMC) including Styrene-Butadiene rubber (SBR), with different weight ratios of polymer to cement: 4%, 8% and 12%. Steel fibers were also included. Sixteen (500mm) diameter, (50mm) thick discs for high-velocity impact tests were used. In addition compressive strength, splitting tensile strength, and flexural strength (modulus of rupture) were companionly recorded. In all the tests, concrete was with and without crimped steel fibers of ratio 1% by volume.In investigating high-velocity impact strength, the decrease in projectile penetration depth was (5-17%) and the scabbing area reduced (15-35%) over reference concrete.In studying PMC including 1% by volume steel fibers, an additional increase was observed in all properties. The increases were quite significant in high-velocity impact strengths. Further reduction was recorded in scabbing area of (64-95%) and penetration depth reduced (28-39%) over control specimens. The fragmentations were reduced also. The range of corresponding compressive was (48-64)MPa ,of splitting tensile strength (4.2-7.8) MPa, and of flexural strength (5-8) MP      

Article
Optimization of Different Properties of Ultra- High Performance Concrete Mixes for Strengthening Purposes

Duaa Suleman, Mahmoud Mohammed, Yousif Mansoor

Pages: 72-85

PDF Full Text
Abstract

The current research’s purpose is to examine how Ultra-High Performance Fiber Concrete (UHPFC) holds up in terms of strength and durability for strengthening purposes. For this reason, the experimental and the theoretical studies in this research attempted to assess different fresh and hardened properties of a variety of ultra-high performance combinations. Steel fibers were utilized to differentiate all of the program's combinations at percentages of  0.25 %, 0.5 %, 0.75 %, 1%, and 1.25 % by volume. Mini flow slump, compressive and flexural strength, ultrasonic pulse velocity, water absorption, and porosity tests were all used to examine the performance of the strength and durability of the material. The findings of this study's trials showed that steel fibers increased the strength of UHPFC. The steel fiber ratio of 1% gave the maximum compressive strength, whereas 1.25 percent yielded the highest flexural strength. Because the fibers function as a bridge, preventing internal breaking, the tensile test results were improved as the proportion of steel fiber rises. Through the use of the multi-objective optimization approach, the optimal ratio of fibers was chosen at the end of the laboratory work since it has the best durability and strength characteristics. Statistical software (Minitab 2018) was used to find the optimal combination of UHPFC that meets all of the requirements. The theoretical selected optimum ratio of 0.77% of fibers obtained from the optimization was evaluated and validated experimentally.  The optimized mix provided 90.28 MPa, 14.6 MPa, and 20.2 MPa for compressive, splitting tensile and flexural tests respectively with better durability performance compared to other mixes prepared in this investigation. 

Article
Performance of Fiber normal – weight concrete Exposed to Elevated Temperatures

nan nan

Pages: 1-14

PDF Full Text
Abstract

The main rule of this search is determining the effect adding various types of fiber to normal concrete mixes on performance normal strength concrete ,it has been used three types of fibers (glass, short steel fibers& long steel fibers)with different contents in mixes(0.5,1.0&1.5%) respectively. It had been cast (210) cubes with dimensions (100×100×100m) mm,(160) cylinders with dimensions (100×200) mm , All concrete specimens heated under different temperatures (100,200,300,400,500 &600 C°) at age 28 days, so that it had been stayed under specified temperatures about two hours then , cooled in naturally in room temperatures and tested in compressive for cubes &splitting strength for cylinders. The results stated that the fiber improve the compressive strength under fire temperatures about (87%) compare with reference mixes, and the fiber glass take little differences than steel fiber in splitting strength when its content reach (1.0,1.5%) respectively and using this types of fibers improved the properties of concrete against the fire.

Article
Experimental Investigation on Mechanical Properties of Normal Concrete Reinforced with Discarded Steel Fibres

Rawaa Obaid, Ahmed Noaman, Akram Mahmoud

Pages: 1-9

PDF Full Text
Abstract

This study presents an investigation of the mechanical properties of normal concrete reinforced with discarded steel fibers (DSFs) resulting from tire manufacturing. DSFs were added to concrete in two different volume fractions of (0.25 %, and 0.5 %), and these fibers have dimensions of (40 mm length×0.92 mm diameter). The results showed that the compressive strength of the concrete was enhanced by (8.8%, and 3.3%) by adding of DSFs. However, the workability of concrete decreased at all added ratios. While the density is slightly changed. Also, the results indicate that the modulus of elasticity shows slight increases by (3.06%, and 2.25%). Additionally, the incorporation of DSFs improves the splitting tensile strength and modulus of rupture significantly. For concrete mixes having volume fractions of 0.25% and 0.5%, the splitting tensile increased by (7.89%, and 23.68%), and the modulus of rupture increased by (6.67% and 25.58%), respectively. It was concluded that using this type of discarded fibers can improve the mechanical properties of concrete as an alternative type for other types of industrial fibers.

Article
Flexural Behavior of Slurry Infiltrated Waste Plastic Fiber Concrete

Dheyaa Ali, Abdulkader Al-Hadithi, Ahmed Farhan

Pages: 42-51

PDF Full Text
Abstract

Slurry infiltrated fiber concrete (SIFCON) is a relatively new high performance material and can be considered a special type of fiber concrete (FRC) with high fiber content. The matrix consists of a flowing mortar or cement slurry that must penetrate well through the network of fibers placed in the mold. SIFCON has excellent mechanical properties combined with high ductility and toughness values. SIFCON a relatively new material, is composed of mud (cement or cement and sand), water, a plasticizer (water reducer), and fibers. All previous studies have used waste steel fibers, steel fibers and other fibers, but in this study, plastic fibers were made from polyethylene terephthalate (PET) by cutting carbonated beverage bottles. The main objectives of this study are: Determination the effect of the waste plastic fiber volume ratio on the strength and deformation of (SIFCON) samples under the influence of bending loads. Both flexural strength and toughness properties were determined by testing samples (100×100×400) mm at 28 and 56 days of age. The results obtained from these tests were compared with those performed on conventional tests. Aspect Ratio equal to (36.8) and three volume ratios (3%, 5% and 7%) of the total volume of the concrete mixture were used to add fibers with different volume ratios. A conventional concrete mix was created as a reference for comparison. Bending strength and fresh concrete tests were performed. And compared with the reference mixture and according to the analysis of the results. The results showed an improvement in bending strength .It was found through the flexural examination that the flexural strength of the mixture containing fiber percentage (7%) achieved the highest strength compared to the rest of the ratios used, compared with the reference mixture (Ref.) by (32.25, 27.5)% for ages (28, 56), respectively.

Article
Stress-Strain Relationship for Steel-Fiber Reinforced Polymer Modified Concrete under Compression

Dr.Abdulkader Ismail Al- Hadithi, Ameer Abdulrahman Al- Dulaimy, Dr .Saeed Khalaf Rejib

Pages: 19-30

PDF Full Text
Abstract

The present study, concern about an experimental work to study the stress-strain relationship of steel-fiber reinforced polymer modified concrete under compression. Four different mixes with weight proportions of (1:2:4) were used as; normal weight concrete (NC), polymer modified concrete (PMC) with (10%) of cement weight and two mixes of steel-fiber polymer modified concrete with (1%) and (2%) volume fraction of steel fiber, (SMPC). The influences of polymer and fiber addition on peak stress, strain at peak stress and the stress-strain curve were investigated for concrete mixes used. For all selected mixes, cubes (150×150×150mm) were made for compressive strength test at (28) days while stress-strain test was caried out on cylinders (150 mm  300 mm) at the same age. Results showed an improvement in compressive strength of polymer modified concrete (PMC) over reference mix, the maximum increase of it was (13.2 %) at age of (28) days. There is also an increase in compressive strength with increasing of steel fibers content with comparison to normal concrete, the maximum increases of it were (19.6% and 25.2%) of mixes with 1% and 2% fiber content by volume respectively. In terms of modulus of elasticity, the addition of polymer and the presence of fibers cause a significant increase in it. The peak of stress- strain curve for normal strength concrete (Mix No.1) was linear whereas it was more sharp for the other mixes. The behaviour of normal strength concrete (Mix No.1) was linear up to 20 % of ultimate strength, while for the mixes with the higher strength i.e. polymer modified concrete and fibers reinforced concrete (Mixes No.2, 3 and 4) the linear portion increases up to about 50 % of ultimate strength

Article
Using Steel Fiber Reinforced Concrete (SFRC) as an Alternative to Negative Reinforcement in Continuous RC Slab Panels

Ali H. Aziz, Mithaq A. Louis, Wissam K. Al-Saraj

Pages: 17-26

PDF Full Text
Abstract

This study presents an experimental investigation performed to investigate the using of steel fiber reinforced concrete (SFRC) as an alternative to negative reinforcement in continuous RC thin slab panels. More rational way has been used by replacing negative reinforcement near interior supports by steel fiber reinforced concrete (SFRC). Tests were carried out on four slab panels, simply supported under single point loading. One of which were made fully with NSC, and the others were made partially with SFRC in negative moment zone. Experimental results show that the ultimate load capacity are increased (23% -58%) and the cracking loads are increased (25% -62.5%) for tested specimens strengthened with SFRC, in comparison with the reference specimens. Crack arrest mechanism of steel fibers limits crack propagation, improves the ultimate and tensile strength. So, more practical technique can be concluded from this study and employed in manufacturing of thin slabs.

Article
Mechanical Properties and Impact Behaviour of Hybrid Fiber Reinforced Rubberized Self-Compacting Concrete

Iman Qadir, Ahmed Noaman

Pages: 69-81

PDF Full Text
Abstract

The problem of discarded tires has received a lot of attention from many authors. Incorporation of rubber aggregate recycled from waste tires is one of the solutions to this issue. This research is based on evaluating fresh and hardened properties such as slump flow, T500, segregation resistance, and L-box tests, compressive strength, impact resistance, and flexural toughness. Rubber aggregate replacements in the self-compact concrete mixes was 10% by volume of fine aggregate. Additionally, both PET and steel fibers are utilized at a volume rate of 0.25%.The outcomes indicate that introducing rubber declines rheological and hardened properties, whereas incorporating hybrid fibers enhances hardened properties such as compressive strength, impact energy, and flexural toughness. The best increase impact energy was obtained at roughly 166.6% when 0.25% hybrid fibers and 10% rubber were used. 74.21 was the greatest increase in flexural toughness when 0.25% hybrid fibers (SCCH3) were used. As for the compressive strength, it was the highest by about 11%.

Article
THE EFFECT OF ADDITION OF STEEL FIBERS ON COMPRESSIVE AND TENSILE STRENGTHS OF STRUCTURAL LIGHTWEIGHT CONCRETE MADE OF BROKEN BRICKS

Mahmoud Kh. Mohammed

Pages: 120-140

PDF Full Text
Abstract

Abstract This research studies the effect of adding steel fiber in two percentage 0.5% and 1% by volume on plain structural lightweight concrete (SLWC) produced by using crushed bricks as coarse lightweight aggregates (LWA) in a lightweight concrete mix designed according to ACI committee 211-2-82 with mix proportion 1:1.12 :3.35 by volume .The wc equal to 0.5 and cement content 550 kgm3. Different tests where performed for fresh and hardened SLWC such slump test ,fresh and hardened unit weight ,compressive strength and two indirect tests of tensile strength (splitting tensile and flexural strength). The results demonstrated that the effect of addition of steel fiber was more pronounced on the tensile strength of SLWC than the compressive strength of such concrete .The maximum increase of compressive ,splitting tensile and flexural strengths at 28-days were 38.8,77.12 and 111.2 % in the SLWC containing 1% fiber. On the other hand the rate of strength gain between 3 and 28 days was constant on compressive strength of plain concrete and that containing steel fiber while this rate was clearly increase on tensile strength especially flexural strength.

Article
NON-LINEAR 3D-FINITE ELEMENT ANALYSIS OF STEEL FIBER REINFORCED CONCRETE MEMEBERS SUBJECTED TO BLAST LOADING

Tariq A. Thaker, Abdulla T. Ameen

Pages: 123-141

PDF Full Text
Abstract

Abstract: This research is devoted to investigate the behavior of steel fiber reinforced concrete members subjected to blast loading. Material nonlinearity due to nonlinear response of concrete in compression, tensile cracking, strain softening after cracking, crushing of concrete and the yielding of steel reinforcement are considered. Three-dimensional finite element is used with eight and twenty-node are hexahedral isoparametric brick element for the spatial discretization. In the idealization of the reinforced concrete structures, the steel reinforcement is incorporated in the concrete brick element as a smeared layer assuming perfect bond. Concrete is modeled as an elasto-viscoplastic model in compression and as a linear elastic strain softening in tension. The steel reinforcement is assumed to have uniaxial properties in the direction of the bars. A classical elasto-viscoplastic model is used to model the reinforcement. Some numerical problems are solved and compared with other studies to verify the applicability and accuracy. Parametric study to investigate the effect of some important parameters has been carried out. The results showed that the use of steel fibers in members subjected to dynamic loading lead to better performance.

Article
Compressive and Impact Loads' Effects on The Behaviour of SIFCON Made of Plastic Waste Fibers

Anas Al-Hadithi, Abdulkader Al-Hadithi

Pages: 44-54

PDF Full Text
Abstract

SIFCON is a relatively new material and consists of slurry (cement or cement and sand), water, super plasticizers (water reducers) and fibers. In all previous research, steel fibers and other types of fibers were used, but in this study, waste plastic fibers Polyethylene Terephthalate (PET) created by cutting carbonated beverage bottles were used for the first time in the production of SIFCON.   Three volume ratios (3%, 6% and 10%) of the total volume of the concrete mixture were used to add fibers in different volume ratios, and a reference concrete mixture was created for comparison. Tests of compressive strength, impact resistance, ultrasound transmission velocity check and other tests were performed on the constructed models. Compared with the reference concrete, according to the analysis of the results. The results showed an improvement in the compressive strength it increased by (18.5%), an increase in the impact resistance by (416.67%), and a decrease in the velocity of ultrasound by (19.42%).

1 - 11 of 11 items

Search Parameters

Journal Logo
Iraqi Journal of Civil Engineering

University of Anbar

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY 4.0 Logo Licensed under CC-BY-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

       
Copyright © 2025 College of Engineering, University of Anbar. All rights reserved, including those for text and data mining, AI training, and similar technologies.